Reliable Controls® building controls products are tested and listed with the BACnet® Testing Laboratory (BTL).
Look for the BTL mark and be confident with your next building automation system integration.
|
|
|
|

Native BACnet® means that the BACnet® operating stack is embedded directly in the device. Every Reliable Controls®
BACnet® Controller has the BACnet® stack at the board level.
Every Reliable Controls®
device is peer-to-peer. There are no additional management devices required for communications with other
vendor's products.

Your building automation system will begin paying dividends immediately through energy savings, and
improved comfort. Future-proof your facility by insisting on native BACnet® Controller products.
BACnet® will not become obsolete. It is an open standard protocol (ASHRAE Standard 135) that
can easily be extended with new features to meet the rapidly changing demands of the Building Automation
industry.
This is accomplished without introducing any incompatibility with existing
BACnet® networks and products. Eliminate obsolescence and save money.
|
|
|
|
|
The Reliable Controls® MACH-System enables you to:
- Build 'native' BACnet® systems exclusively with Reliable Controls® BACnet® Controller products.
- Use the BACnet® protocol to interface with Original Equipment Manufacturers products.
- Add to another vendor's native BACnet® system using Reliable Controls® products.
- Mix legacy Reliable Controls® products and BACnet® protocol networks into one system.
- Upgrade all earlier versions of MACH controllers (Air, Zone, 1, 2, Net) to native BACnet® networking.
- Configure a BACnet® controller for either BACnet® or Reliable Controls® protocol while in the field.
- Operate a Reliable Controls® 'native' BACnet® system with another vendor's BACnet® software.
|
|
|
Reliable Controls® MULTI-VENDOR BACnet® Installations
All Reliable Controls® MACH-System sites are 'native' BACnet®.
The table below highlights some multi-vendor installations.
| Project |
Vendors |
System |
Network |
Components |
The Eye Center Columbus, OH, USA |
Reliable |
Distributed |
BACnet MS/TP, BACnet IP Backbone |
MACH-Global, ETHER-Link Portal |
Metropolis at Metrotown Burnaby, BC, Canada |
Reliable & McQuay |
Distributed |
B/IP, MS/TP, and Ethernet |
MACH-Global, ETHER-Link, McQuay Chillers & RTUs |
Metropolitan Museum of Art Washington, DC, USA |
Reliable & Iconics, Staefa |
Distributed |
Wireless, MS/TP, B/IP, and Ethernet |
MACH-Global, Iconics HVAC / Lighting & Staefa |
US Department of Transportation Washington, DC, USA |
Reliable & Trane BCU |
Distributed |
B/IP, MS/TP, and Ethernet |
ETHER-Link, TRANE BCU |
Ping An Insurance Pudong New District, Shanghai, China |
Reliable & Trane BCU, Daikin |
Distributed |
B/IP, MS/TP, and Ethernet |
MACH-Global, TRANE BCU, & DAIKIN Gateways |
Long Zhu Hospital Shenzhen, China |
Reliable & Cimetrics |
Distributed |
B/IP, MS/TP, and Ethernet |
MACH-Global, Cimetrics BACnet® / OPC |
River Rock Casino Resort Richmond, BC Canada |
Reliable & Trane BCU |
Distributed |
B/IP, MS/TP, and Ethernet |
MACH-Global |
Montgomery College Campus, MD USA |
Reliable & Alerton, ALC, Delta |
Distributed |
B/IP, MS/TP & Ethernet |
ETHER-Link, BTI B-ASC from all vendors B-OWS from all vendors |
Architect of the Capital Washington, DC USA |
Reliable & Alerton, ALC, Delta |
Chiller |
B/IP, Ethernet & MS/TP |
ETHER-Link, BTI B-ASC from all vendors B-OWS from all vendors |
Jean Talon Building Ottawa, ON Canada |
Reliable & Delta |
Distributed |
Ethernet & MS/TP |
ETHER-Link & ORCA |
Research In Motion (RIM) Waterloo, ON Canada |
Reliable & Delta |
Chiller |
Ethernet & MS/TP |
MODBUS-Link & Delta BAS |
Colorado Square Colorado Springs, CO USA |
Reliable & ALC |
Distributed |
B/IP & MS/TP |
MACH-Global, MACH-Zone, WebCTRL, LGE |
AmeriCredit Headquarters Forth Worth, TX USA |
Reliable & Carrier |
Chiller |
Ethernet |
ETHER-Link & BAClink |
Telus Building Rimouski, QC Canada |
Reliable & Trane |
Distributed |
Ethernet & MS/TP |
ETHER-Link & Trane VAV |
Ecole Notre Dame St. Nagaire, QC Canada |
Reliable & Delta |
Distributed |
Ethernet & MS/TP |
ETHER-Link & ORCA |
Paducah Community College Paducah, KY USA |
Reliable & Alerton |
Distributed |
Ethernet |
ETHER-Link & LSI, BACtalk |
Workers Compensation Board Richmond, BC Canada |
Reliable & Carrier |
Chiller |
Ethernet |
ETHER-Link & BAClink |
West End Community Centre Guelph, ON Canada |
Reliable & Douglas |
Lighting |
PTP |
ETHER-Link & BAClight |
Telus - Chomedey Laval, QC Canada |
Reliable & Liebert |
Computer Room |
PTP |
MACH-Net & Sitelink |
Telus - Viger Montreal, QC Canada |
Reliable & Liebert |
Computer Room |
PTP |
MACH-Net & Sitelink |
RCMP-K Edmonton, AB Canada |
Reliable & Trane |
Chiller |
PTP |
MACH-Net & Summit BCU |
|
BACnet® Links
The BACnet® Conference & Expo is an annual educational event for end-users, consultants, and integrators
who wanted to learn more about BACnet®. For more information on the event:
[Visit the BACnet Conference and Expo website]
|
|
BACnet® International is an organization that encourages the successful use of BACnet® in building automation
and control systems through interoperability testing, educational programs, and promotional activities. For more
information on the organisation or to become a member:
[Visit the BACnet® International website]
|
 |
|
BACnet® Interest Group Europe e.V. (BIG-EU) is an organization whose goal and objective are to lower building costs and greater
energy efficiency. It is because systems that communicate with each other in a single language are far superior to isolated solutions,
that we demand the prevalence of the BACnet standard in Europe. For more information on the organisation:
[Visit the BACnet® Interest Group - Europe website]
|
 |
|
BACnet® - A Data Communication Protocol for Building Automation and Control Networks. Developed under the
auspices of the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE), BACnet® is
an American national standard, a European standard, and an ISO global standard. For more information on the protocol:
[Visit BACnet - ASHRAE Standard 135 website]
|
 |
|
|
|
|